Chiller RP con Refrigeranti Green

RP Green Chiller with Environmentally-Friendly Refrigerants

Environmental sustainability and performance
Temperature range: from 1°C up to 25°C
-20 -10 0 10 20 30 40 50

High energy savings, low environmental impact, compliance with stringent European regulations: green RP model chillers, with R32 or R290 refrigerant, are the industrial refrigeration solution of the future. Small footprint and provision for remote control are Frigofluid’s signature to these innovative equipment.

Sustainable refrigerants.

Sustainable refrigerants. R290 (GWP 3) and R32 (GWP 675).

Compliance with stringent European standards.

Compliance with stringent European standards. R290 (GWP 3) and R32 (GWP 675) comply with the newly revised EU Regulation No. 517/2014 and EU Regulation No. 1907/2006 “Reach.”

Small footprint.

Small footprint. Ideal for small facilities and small spaces.

Innovative components.

Innovative components. Scroll compressors, micro-channel condensers.

Prepared for remote monitoring.

Prepared for remote monitoring. A serial port can be combined with the machinery for interface connection with remote station.

RP industrial chillers with green refrigerants: description

The new range of Frigofluid RP series air chillers is the answer to the increasingly stringent requirements for energy efficiency, environmental sustainability and performance in industrial refrigeration.

Their key feature is their low environmental impact: they use natural refrigerants with low GWP (Global Warming Potential), namely R290 (propane) and R32 (difluoromethane). These gases have no potential to form PFAS (perfluorinated alkylated substances) when broken down in the atmosphere.

RP chillers are available in 8 models with cooling capacities ranging from 5 to 35 kW and operate over a flow temperature range of 1°C to 25°C.

With the new range of RP chillers, Frigofluid confirms its commitment to finding innovative and sustainable solutions for industrial refrigeration. RP chillers offer the perfect integration of energy efficiency, environmental friendliness and high performance, representing the ideal choice for companies wishing to reduce their environmental impact and optimize operating costs.

Tell us your needs
Chiller RP con Refrigeranti Green

RP industrial chillers with R290 refrigerant: technical characteristics

  • Refrigerant: R290 (propane).
  • Cooling capacity: 5 to 12 kW.
  • Flow temperature: 1° C to 25°C.
  • EER: up to 4.79.
  • SEPR HT: up to 6.79.
  • Environmental impact: low GWP, no PFAS.
  • Components: scroll compressors, micro-channel condensers.

RP industrial chillers with R32 refrigerant: technical characteristics

  • Refrigerant: R32 (difluoromethane).
  • Cooling capacity: 15-35 kW.
  • Flow temperature: from 1° C to 25°C.
  • EER: up to 3.85.
  • SEPR HT: up to 5.66.
  • Environmental impact: low GWP, no PFAS.
  • Components: scroll or rotary compressors, micro-channel condensers.
Ask for Information

Series components on all Frigofluid chillers

Industrial Chiller Series Components
  • 1. EC (electronic control) Axial Fans

  • 2. Microchannel Condenser

  • 3. Compressors

  • 4. AISI 316 SS Plate Evaporator

  • 5. Storage tank

  • 6. Electronic Microprocessor for the hydraulic and Chilling Systems

EC Brushless Industrial Chiller Fans
1

EC (electronic control) Axial Fans

As standard over the entire production range. They guarantee high performance at top speed and control in the slowrunning range.

Industrial Chiller Plate Condenser
2

Microchannel Condenser

Featuring a wide exchange surface and subcooling system plus epoxy paint surface treatment as standard.

Scroll Compressors of Industrial Chillers
3

Compressors

Hermetic systems of “Scroll” type on all models in the catalog.

Industrial Chiller Evaporator
4

AISI 316 SS Plate Evaporator

Or tube-nest evaporator. With foam closecell thermal insulation.

Industrial Chiller Storage Tank
5

Storage tank

In zinc-plated steel featuring close-cell foam insulation and a range of accessories: air exhaust, safety valve, discharge valve, fittings for level control.

Electronic Microprocessor of Industrial Chillers
6

Electronic Microprocessor for the hydraulic and Chilling Systems

Allowing control of the (glycol-added) water temperature and display of the chilling gas operating pressure with remote diagnostics possibility: an alpha-numeric display shows the unit’s working status. In the units with more than one compressor, the microprocessor controls their starts on a rotation basis in order to balance their operating hours.

Manual By-Pass for Industrial Chillers

Manual By-Pass

An accessory designed for the function of adjusting the flow rate of water or water/glycol from a hydraulic circuit so as to obtain a working condition suitable for the chiller and its use. This adjustment is carried out by controlling the discharge pressure of the chiller pump.

Expansion Vessel for Industrial Chillers

Expansion Vessel Kit

An accessory designed for the function of containing changes in "hydrostatic" pressure in a type "C" (pressurized) hydraulic circuit due to changes in water and/or water/glycol liquid temperature.

Expansion Vessel for Industrial Chillers

Outdoor Kit

This is an accessory consisting of 3 elements that ensure IP 55 watertightness of the electrical panel and its components for outdoor installation without any canopy or other protection. With OPT 01250 a cover is applied on the electrical box that protects the gasket of the switchboard door.

Modbus for Industrial Chillers

RTU Modbus

Allows communication of data from our control panels with supervisory and/or other systems through a modbus communication but also OPC UA and PROFINET.

Automatic Loading for Industrial Chillers

Automatic Loading

Hydraulic system aimed at controlling the filling from water or water/glycol of hydraulic circuits. Consisting of accessories and fittings, it is installed on RW power plants, RAW coolers, and systems in general.

Water Filter for Industrial Chillers

Water Filter

Mechanical filter installed on the water inlet pipe to the chiller (return). The filter usually Y-type can be bronze for sections up to 2" ½ max 3", or spheroidal cast iron flanged for sections 3" and up.

Some Frigofluid projects

Tools to help you choose

Preliminary Assessment

Many interlocutors come to us with a very general idea of their industrial refrigeration needs: this is normal. That's why we stimulate the sharing of technical information.

Customized Design

We believe that integration with the best accessories on the market and the careful and 'unified' selection of internal components can make the difference.

Custom Chillers and Turnkey Plants

Production facilities and the characteristic of the installation area also have important effects on the design: because one cannot stop at the listed solutions.